Connector Test Equipment Overview
Specialized equipment designed to measure moisture loss values in inline connectors during operational use, ensuring product reliability and performance standards.
Equipment Control and Operation
Control Functions
Power Off/On: Controls main equipment power supply
Emergency Stop: Immediately halts all equipment operations in emergency situations
Test Operation Procedure
  • Activate power switch (Off/On) to access system login interface
  • Select system entry to reach main operation page
Breathing System Configuration
Breathing Settings
Function Description
Tidal Volume Selection Set tidal volume parameter - breathing frequency automatically adjusts once volume is confirmed
Homing Function Return to origin position - testing should always initiate from origin point
Breathe Start/Stop Control breathing cycle initiation and termination
Breathing Time Management
Control Function
Timing Switch Activate timer - heating and breathing automatically cease when timing completes
Time SV Set breathing duration parameters
Time PV Display current breathing time progress
Flow Monitoring System
Total Exhalation Volume (V): Cumulative breathing volume automatically calculated from set tidal volume and breathing duration. For accurate results, set breathing time first, then configure tidal volume.
Heating System Controls
Temperature Regulation
Control Function
Heating Switch Activate heating system functionality
Sink Temperature: SV Set water tank heating temperature parameters
Sink Temperature: PV Display current water tank temperature readings
Box Temperature: SV Set chamber heating temperature parameters
Box Temperature: PV Display current chamber temperature readings
Temperature Monitoring
Real-time temperature curve display showing one-hour historical data with color-coded differentiation between water tank and chamber temperatures.
Weighing and Measurement System
Weighing Controls
Function Description
Current Weight Real-time weight measurement display
Zero/Tare Tare functionality - perform tare operation before weighing to ensure measurement accuracy
Weight Weighing activation - click to initiate weighing, click again to cancel
Records Delete Clear recorded weight data - erases stored m0, m1, m2 values
Record Weight recording function
Weight Recording Protocol
  • m0: Record pre-test baseline weight measurement
  • m1, m2: Record post-test weight measurements for comparison
Moisture Loss Rate Calculation
Automated calculation system determines moisture loss rate using recorded weights (m0, m1, m2) and cumulative volume (V). Manual input capability available for customized calculations and verification.
produits
DéTAILS DES PRODUITS
connector test equipment
MOQ: 1
Prix: to be quoted
Emballage Standard: boîte en contreplaqué
Période De Livraison: 25 JOURS OUVRABLES
Méthode De Paiement: T/T
Capacité D'approvisionnement: 20 unités par mois
Les informations détaillées
Lieu d'origine
CN
Nom de marque
kingpo
Certification
ISO 17025 calibration certificate
Quantité de commande min:
1
Prix:
to be quoted
Détails d'emballage:
boîte en contreplaqué
Délai de livraison:
25 JOURS OUVRABLES
Conditions de paiement:
T/T
Capacité d'approvisionnement:
20 unités par mois
Mettre en évidence

connector test equipment with warranty

,

lamp cap gauge tester

,

electrical connector testing tool

Description de produit
Connector Test Equipment Overview
Specialized equipment designed to measure moisture loss values in inline connectors during operational use, ensuring product reliability and performance standards.
Equipment Control and Operation
Control Functions
Power Off/On: Controls main equipment power supply
Emergency Stop: Immediately halts all equipment operations in emergency situations
Test Operation Procedure
  • Activate power switch (Off/On) to access system login interface
  • Select system entry to reach main operation page
Breathing System Configuration
Breathing Settings
Function Description
Tidal Volume Selection Set tidal volume parameter - breathing frequency automatically adjusts once volume is confirmed
Homing Function Return to origin position - testing should always initiate from origin point
Breathe Start/Stop Control breathing cycle initiation and termination
Breathing Time Management
Control Function
Timing Switch Activate timer - heating and breathing automatically cease when timing completes
Time SV Set breathing duration parameters
Time PV Display current breathing time progress
Flow Monitoring System
Total Exhalation Volume (V): Cumulative breathing volume automatically calculated from set tidal volume and breathing duration. For accurate results, set breathing time first, then configure tidal volume.
Heating System Controls
Temperature Regulation
Control Function
Heating Switch Activate heating system functionality
Sink Temperature: SV Set water tank heating temperature parameters
Sink Temperature: PV Display current water tank temperature readings
Box Temperature: SV Set chamber heating temperature parameters
Box Temperature: PV Display current chamber temperature readings
Temperature Monitoring
Real-time temperature curve display showing one-hour historical data with color-coded differentiation between water tank and chamber temperatures.
Weighing and Measurement System
Weighing Controls
Function Description
Current Weight Real-time weight measurement display
Zero/Tare Tare functionality - perform tare operation before weighing to ensure measurement accuracy
Weight Weighing activation - click to initiate weighing, click again to cancel
Records Delete Clear recorded weight data - erases stored m0, m1, m2 values
Record Weight recording function
Weight Recording Protocol
  • m0: Record pre-test baseline weight measurement
  • m1, m2: Record post-test weight measurements for comparison
Moisture Loss Rate Calculation
Automated calculation system determines moisture loss rate using recorded weights (m0, m1, m2) and cumulative volume (V). Manual input capability available for customized calculations and verification.